Utilizing a signal from transistor transistor logic (TTL) circuits, the integrated power switch (IPS) can control 40 kW. Protection against overload conditions enables the use of transistors which have ideal switching characteristics. Each half-section of the IPS is electrically isolated from the signal input using optical couplers. Discrete component assemblies, printed-circuit boards, thick-film or medium-scale integrated substrates each have been utilized. The forced-air-cooled heat sink was designed for maximum cooling. Two types of IPS's were initially constructed: 500 V/60 A, and 100 V/200 A, with additional availability of 500 V/100 A devices in small quantity. Its capability to work from continuous operation to 10 kHz makes the IPS universally applicable to most power-conversion applications with-in its current and voltage limitation.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.