Abstract

To discuss the technique of installation of zygomatic implants in severely resorbed edentulous maxillae, and maxillary defect. Five patients received 8 zygoma implants and 11 dental implants. On the basis of an axial spiral CT data, anatomical models of natural size were manufactured using CAD/CAM system and before operation preoperative measurements of relevant parameters (length, areas, and volumes) carried out. Theses maxillary and zygomatic measurements obtained were referred for installing zygomatic implants. The ideal direction and position of installation of the 8 zygomatic fixtures were obtained in 5 patients. The anatomical model and surgical plate were used for preoperative planning and intraoperative control of the insertion of zygomatic fixtures. The implants could be positioned precisely as preoperatively planned. The length of the zygomatic implants was between 40 mm and 50 mm. The use of surgical drilling guides should be encouraged for zygomatic implant placement. 3-D image data and anatomical models improves preoperative planning and facilitates clinical procedure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.