A novel and sensitive electrochemical sensor based on magnetic porous pseudo-carbon paste electrode (MPPCPE) for schistosoma egg antigen (SEA) detection was described. The influences of immune reaction conditions such as time, pH and temperature on the detection current were investigated, and the influences of the blocking times of mercaptoethanol and ethanolamine on the background current were investigated. The experimental results shown that the high detection current and low background current could be obtained when the immune reaction temperature was 30 degrees C, the immune reaction time was 40 min, the immune reaction pH was 7.2, the blocking time of ethanolamine was 40 min, and the blocking time of mercaptoethanol was 60 min. At the optimum reaction conditions, a limit of detecting SEA as low as 0.01 microg/mL was obtained using MPPCPE.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.