Abstract
As a basic theoretical research for the ultra efficiency motor design, in this paper, the influence of wye and delta connection on induction motor losses is focused on. The Multi-slice field-circuit coupled time-stepping finite element method (T-S FEM), taking slot opening and skew effect into account, is used to predict the losseswith wye and delta connection under different load conditions respectively. It is shown that the copper loss is higher when delta connection is adopted and the iron losses of wye connection may be more than that of the delta connection.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.