Abstract

BackgroundSurgical repair of functional tricuspid regurgitation is centered on annular reduction with artificial rings; however, the precise effect of prosthesis implantation on annular geometry, dynamics, and strain is unknown. MethodsForty healthy sheep had sonomicrometry crystals implanted around the tricuspid annulus and onto right ventricle free wall. Ten animals underwent tricuspid annuloplasty with a flexible Duran AnCore ring (Medtronic, Minneapolis, Minn) (28 ± 1 mm), 10 with Contour 3D rigid ring (Medtronic) (29 ± 1 mm), 10 with hybrid Tri-Ad Adams band (Medtronic) (28 ± 1 mm), and 10 had no prosthesis (control group). Pressure sensors were inserted in the left ventricle, right ventricle, and right atrium. Data were acquired with open chest after weaning off cardiopulmonary bypass and hemodynamic stabilization. Annular area, global and regional contraction, height, and strain were calculated based on cubic spline fits to crystal locations. ResultsTricuspid annular area contraction during the cardiac cycle was 11% ± 3% in the control group. The Contour 3D ring significantly impaired annular contraction (2% ± 1%) whereas the Duran AnCore ring and Tri-Ad Adams band (9% ± 3% and 8% ± 4%, respectively) permitted dynamic area change. Global perimeter reduction was 6% ± 1% in the control group and decreased in the Duran AnCore (3% ± 1%), Contour 3D (0.4% ± 0.2%), and Tri-Ad Adams (3% ± 1%) groups (all P values < .001 vs control). Annular height was 6.2 ± 2.0 mm in the control group, unchanged in the Contour 3D (4.9 ± 1.1 mm) but reduced in the Duran AnCore (3.1 ± 1.3 mm) and Tri-Ad Adams (3.1 ± 1.0 mm) groups (P < .001 Duran AnCore and Tri-Ad Adams vs control). Rings perturbed systolic global annular strain (control, 5.3% ± 1.8%; Duran AnCore, 2.3% ± 1.0%; Contour 3D, 0.6% ± 0.2%; and Tri-Ad Adams, –2.6% ± 0.7%) with Contour 3D inducing the biggest change (P < .05 vs other groups). ConclusionsIn healthy ovine hearts, flexible and hybrid rings better preserved annular dynamics and strain, whereas the rigid ring maintained 3-dimensional geometry. These data may aid the design of optimal tricuspid annular prostheses and improve durability of valve repair.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.