Abstract
Serial arterial blood gases were measured during fibreoptic bronchoscopy in 26 patients with diffuse interstitial lung disease. All those having transbronchial biopsy with or without bronchoalveolar lavage, performed breathing room air, showed significant falls in Pa o 2, at the time of passage of the bronchoscope through the vocal cords both at the beginning and end of the procedure. Patients having bronchoalveolar lavage and transbronchial biopsy performed with supplementary oxygen at least maintained their basal Pa o 2 levels. Cessation of the supplementary oxygen 30 minutes after withdrawal of the bronchoscope did not result in rebound hypoxaemia. Bronchoalveolar lavage and transbronchial biopsy can be performed safely in patients with diffuse interstitial lung disease without significant hypoxaemia developing, if oxygen is started before the procedure and continued for 30 minutes after withdrawal of the bronchoscope.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.