Abstract

PurposeThe therapeutic success of minimal invasive glaucoma surgery (MIGS) is challenging due to many factors including fibrotic or occlusive events. Recent clinical data show sudden peaks of intraocular pressure (IOP) in the postoperative care of glaucoma patients after suprachoroidal draining stents. Yet, the reasons for the IOP peaks are speculative. As a link between trace elements and fibrosis had been previously observed in systemic disorders, the present study aimed to investigate the impact of trace elements on the therapeutic success of the suprachoroidal draining stents in patients with open-angle glaucoma (OAG). Material and MethodsAn analysis of a prospective single-center study was done: fifty-five eyes of patients with OAG (29 female, 26 male) underwent Cypass Micro-Stent implantation either as a stand-alone procedure or combined with cataract surgery. All patients underwent pre-operatively an ophthalmological examination which included slit lamp biomicroscopy and fundoscopy. IOP was measured by Goldmann applanation tonometry. Functional and morphometric data were assessed by Octopus G1-perimetry, which included measurement of retinal nerve fiber layer thickness (Spectralis OCT). Data of the patients’ follow-ups were recorded during 18 months post-operatively. The therapeutic success of CyPass Micro-Stent was classified as ‘success’ (IOP reduction ≥20% compared to a pre-operative baseline without any medication), ‘qualified success’ (IOP reduction ≥20 % with same or lower additional eye medication), and ‘failure’ (IOP reduction ≤20 % or additional surgical treatment necessary). Aqueous humour was extracted once during surgery for analysis of the level of 14 trace elements: Copper (Cu), Cadmium (Cd), Cobalt (Co), Chromium (Cr), Iron (Fe), Lithium (Li), Magnesium (Mg), Manganese (Mn), Phosphorus (P), Lead (Pb), Titanium (Ti), Uranium (U), Vanadium (V), and Zinc (Zn). Analysis of the trace elements was done using an ELEMENT 2, ICP-sf-MS instrument (Thermo-Fisher Scientific, Bremen, Germany). Analysis of levels of trace elements was done across the patients’ groups of the three subclasses of therapeutic success. Statistical investigations for substantial differences were conducted using the method of least squares to fit general linear models and mixed models. The last one for the repeated measurements of IOP. ResultsLevels of Mg were significantly lower one month postoperatively in the success group (LS-Mean 1.30 mg/L) compared to the qualified success group (LS-Mean 1.22 mg/L; p-value = 0.04). Fe was significantly increased in the failure group (LS-Mean 2.07 µg/L) compared to the qualified success group (LS-Mean 1.64 µg/L; p-value = 0.019) after 3 months of follow-up. Additionally, Fe levels were significantly lower in the success group (LS-Mean 1.47 µg/L) compared to the failure cohort (LS-Mean 2.07 µg/L; p-value = 0.009). After a period of 18 months, significantly higher levels of Mn were observed in the success group (LS-Mean 1.24 µg/L) than in the failure group (LS Mean 0.30 µg/L, p-value = 0.019). ConclusionThe present data might suggest that trace elements can influence therapeutic success of suprachoroidal draining devices postoperatively and thus offer first hints for potential novel therapeutic options.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.