Abstract

The turbulent forced convection heat transfer of rectangular fins in a duct was investigated by varying the tip clearance and Pr. Mass transfer experiments using a H2SO4–CuSO4 electroplating system were performed based on the analogy between heat and mass transfers. FLUENT 6.3 was used for calculations. Turbulent models were tested and the Reynolds Stress Model was chosen, which showed a 1.15 % discrepancy with the existing correlation for a simple tube flow when Pr = 2, but 13 % when Pr = 2014. For a more complex fin channel, the discrepancy increased up to 30 %. The optimal tip clearances, corresponding to maximum heat transfer rates, did not vary with Pr, which is explained using the temperature contours. The results were also compared with the laminar case where Pr influenced the optimal tip clearance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.