Abstract
Absorption-controlled charge and discharge currents in cross-linked polyethylene (XPE) cable insulation before and after thermal aging have been measured. The experimental dependences were analyzed in terms of the equivalent Voigt scheme. Known parameters of the Voigt scheme were used to calculate the frequency dependences of relative dielectric permittivity, loss factor, and loss tangent of XPE films in the region of low frequencies (ω = 10–3–1 s–1) at high temperatures. Results of analysis of the absorption characteristics of XPE were applied to modeling of the process of thermal aging of cable insulation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.