Abstract

The article presents a study on the influence of shock wave on a Hybrid III anthropomorphic test device (ATD HIII) equipped with an explosive ordnance disposal (EOD) suit. The shock wave was generated by the detonation of SEMTEX 1A plastic explosive, formed in the shape of a 250 g, 500 g, and 840 g sphere, at a distance of 0.5 m, 1 m, and 2 m. The use of ATD allowed for determining parameters of damage to the human body as a result of the impact of overpressure wave. The experiments also included a measurement of such parameters as forces and moments on lower extremi-ties, acceleration of head and pelvis, and forces and moments on a neck simulator. Chest Wall Velocity Predictor (CWVP), calculated from the pressure measured on ADT’s chest, was adopted as the most critical parameter. It was revealed that the allowed distance of explosion of a 500 g pure explosive, which does not cause exceeding the allowed parameters, is 1 m.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.