Abstract

A theoretical expression has been derived for the dependence of the discharge capacity, C, of the positive plate of the lead—acid battery, on the temperature, T, in the form dln C/d T = ( k - 1)(dlnκ/d T + 1/ T), where k is the coefficient of Peukert's equation and κ is the specific conductivity of the electrolyte. This formula was confirmed by measurements on SLI battery positive plates.