Abstract

This paper aims to show how the switching frequency influences the properties of the digitally controlled voltage source inverter (VSI). The measurements of the Bode plots of the inverter are shown and discussed to present the existing signal delays and power conversion efficiency, depending on the switching/sampling frequency. Two types of controllers are presented, Single-Input–Single-Output (SISO) and Multi-Input–Single-Output (MISO), and adequate prediction units (the Smith Predictor for SISO—Coefficient Diagram Method and the full-state Luenberger Observer for MISO—Passivity Based Control) were used to compensate for the delays. It will be shown by comparing the THD of the VSI output voltage that prediction is useful with low VSI switching frequency (about 10 kHz) but is not important for the middle switching frequencies (about 25 kHz) or the high switching frequency (>50 kHz). This paper shows that increasing the switching frequency simplifies digital control without reasonably decreasing efficiency. The theoretical considerations, the Matlab/Simulink 2021b simulations, the final experimental laboratory verification are presented.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.