Abstract

The usefulness of the push-out test as an indicator of interface strength was evaluated using finite element models of intact and partially failed cylindrical push-out specimens loaded against a rigid annular support. The irregular stress distributions that were found in intact specimens depended more on interface conditions at the loading fixture than on a 35% increase in interface area. The maximum stress at the interface was a tensile stress. Critical energy release rates for interface failure were calculated for flawed specimens in which flaw size was either 10 or 100 microns, and for boundary conditions at the loading fixture that were either fixed or slipping in the radial direction. The critical energy release rates depended heavily on the support boundary conditions. Thus, the results of parametric push-out tests can be reasonably compared only for specimens that are very similar in geometry and that are loaded in very carefully controlled fixtures.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.