Abstract
Liquid jet impingement is used in industries for cleaning or cooling the surfaces, since this process is characterized by high heat or mass transport rates. The impinging jet spreads radially outwards and creates a wall film flow, which is bounded by a hydraulic jump. The existing models describing the extent of the radial flow zone and the position of hydraulic jump are only applicable for small nozzle-to-target distances and low flow rates. In this work, the model is extended to include the effect of splattering liquid, which may reduce the extent of the radial flow zone considerably. The splattering in combination with the hydraulic jump position is investigated experimentally for a liquid jet impinging horizontally onto a vertical wall. In addition, the high-speed images of the jet and of the impingement region provide further insight into the splattering mechanisms. It is found that for large nozzle-to-target distances the splattered mass fraction is determined only by the jet Weber number. The hydraulic jump position can be predicted using the extended model with deviations of less than 20% in this region.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.