Abstract

BackgroundThis planning study compares different radiotherapy techniques for patients with pituitary adenoma, including flatness filter free mode (FFF), concerning plan quality and secondary malignancies for potentially young patients. The flatness filter has been described as main source of photon scatter.Material and methodsEleven patients with pituitary adenoma were included. An Elekta Synergy™ linac was used in the treatment planning system Oncentra® and for the measurements. 3D plans, IMRT, and VMAT plans and non-coplanar varieties were considered. The plan quality was evaluated regarding homogeneity, conformity, delivery time and dose to the organs at risk. The secondary malignancy risk was calculated from dose volume data and from measured dose to the periphery using different models for carcinoma and sarcoma risk.ResultsThe homogeneity and conformity were nearly unchanged with and without flattening filter, neither was the delivery time found substantively different. VMAT plans were more homogenous, conformal and faster in delivery than IMRT plans. The secondary cancer risk was reduced with FFF both in the treated region and in the periphery. VMAT plans resulted in a higher secondary brain cancer risk than IMRT plans, but the risk for secondary peripheral cancer was reduced. Secondary sarcoma risk plays a minor role. No advantage was found for non-coplanar techniques. The FFF delivery times were not shortened due to additional monitor units needed and technical limitations. The risk for secondary brain cancer seems to depend on the irradiated volume. Secondary sarcoma risk is much smaller than carcinoma risk in accordance to the results of the atomic bomb survivors. The reduction of the peripheral dose and resulting secondary malignancy risk for FFF is statistically significant. However, it is negligible in comparison to the risk in the treated region.ConclusionTreatments with FFF can reduce secondary malignancy risk while retaining similar quality as with flattening filter and should be preferred. VMAT plans show the best plan quality combined with lowest peripheral secondary malignancy risk, but highest level of second brain cancer risk. Taking this into account VMAT FFF seems the most advantageous technique for the treatment of pituitary adenomas with the given equipment.

Highlights

  • This planning study compares different radiotherapy techniques for patients with pituitary adenoma, including flatness filter free mode (FFF), concerning plan quality and secondary malignancies for potentially young patients

  • volumetric modulated arc (VMAT) plans resulted in a higher secondary brain cancer risk than intensity modulated radiotherapy (IMRT) plans, but the risk for secondary peripheral cancer was reduced

  • VMAT plans show the best plan quality combined with lowest peripheral secondary malignancy risk, but highest level of second brain cancer risk

Read more

Summary

Introduction

This planning study compares different radiotherapy techniques for patients with pituitary adenoma, including flatness filter free mode (FFF), concerning plan quality and secondary malignancies for potentially young patients. FFF is applicable in combination with fluence modulating techniques like IMRT or VMAT In this mode a considerably higher dose rate is achieved by omitting the flatness filter. This planning study compares different plans for patients with pituitary adenoma. The aim of this study is to evaluate statistically significant differences for FB and FFF plans regarding the plan quality and the risk for secondary malignancies in the treated region and the periphery. Plans with two and three fixed beams were taken as reference

Objectives
Methods
Results
Discussion
Conclusion