Abstract

Simple SummaryRadiotherapy is an established method of cancer treatment, improving patients’ survival; however, it is associated with possible life-limiting late complications, including cardiovascular diseases. The cardiotoxic effects depend on the doses of radiation delivered to the heart. Despite significant advances in radiotherapy techniques, resulting in reduced doses of ionising radiation, cardiac dysfunction remains a common problem after mediastinal irradiation. The present study emphasises the need to calculate the radiation doses delivered to several parts of the heart, revealing relationships between doses delivered to the left anterior descending artery (LAD) and the whole heart, along with echocardiographic markers of early systolic dysfunction of the left (LV) and right ventricles (RV).The aim of this study was to assess the effects of radiotherapy involving the heart on LV and RV function using modern speckle-tracking echocardiography (STE), and in relation to the radiation dose applied to the LAD. This retrospective, single-centre study included 12 patients after a median of 51 months after irradiation for mediastinal lymphoma, in whom we were able to delineate the LAD. Correlations between doses of ionising radiation and echocardiographic parameters reflecting the systolic function of the LV and RV were analysed. The median irradiation dose delivered to the whole heart was 16.4 Gy (0.5–36.2 Gy), and to the LAD it was 15.1 Gy (0.3–35.3 Gy). LV longitudinal strain (LS) was impaired in the anteroseptal and anterior walls. Parameters reflecting RV function were normal, with the exception of RV myocardial performance index (RIMP). Significant correlations were found between the median dose to the LAD and LV global LS (rho = 0.6468, p = 0.034), the maximum dose to the LAD and LV anterior LS (rho = 0.6046, p = 0.049), the median and the mean dose to the whole heart and LV anterior LS (R = 0.772, p = 0.009 and rho = 0.7676, p = 0.01, respectively), and the total irradiation dose and RIMP (rho = 0.5981, p = 0.04). The calculation of irradiation doses allows the identification of patients at risk of cardiac dysfunction detected by modern STE.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.