Abstract

The retention of hydrogen isotopes in the plasma-facing materials of a fusion reactor is dependent on the density of trapping sites in the material. One factor that can influence the trapping defects is the surface state of the material before exposure. Mechanically polished, electropolished, and recrystallized tungsten samples were compared by exposing them to 350 eV D+ beams with peak fluences of ~1 × 1024 D+/m2 at 500 and 740 K at the Multicharged Ion Research Facility (MIRF). At the exposure temperature of 740 K, no significant retention was detected. For material exposed at 500 K, significant differences in retention were observed, and the order of increasing retention was recrystallized, electropolished, and mechanically polished. The other variable besides surface treatment was the time delay between ion exposure and thermal desorption spectroscopy which also may have impacted the retention measurements if there was out-gassing of the D while samples were in storage before thermal desorption spectroscopy (TDS).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.