Abstract
The morphology of copper deposits formed by pulse plating from an acid sulphate electrolyte is investigated. The steady and non-steady state conditions of mass transport are controlled by use of a rotating hemispherical electrode. Below the limiting pulse current density (ipl), granular deposits are observed. Aboveipl, regardless of the individual values of the pulse parameters, dendritic deposits are formed. Measured current efficiencies are compared with a theoretical model, which predicts a rapid decrease of the efficiency with the increasing ofip/ipl forip/ipl greater than one, whereip is the applied pulse current density. For a given set of pulse parameters, the measured current efficiency increases with the deposit thickness due to the increase of the effective surface area. This effect is particularly important for dendritic deposits.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.