Abstract

Background: The proper sealing of the root canal seems to be critical to obtain a stable result of endodontic therapy. The sealer’s penetration into dentinal tubules during root canal treatment is probably a crucial factor to provide better clinical results. The aim of this study was to compare the effect of three irrigation protocols on the penetration of the epoxy sealer into dentinal tubules and two dyes used to stain the sealer. Methods: Ninety single-canaled human teeth with straight roots were used. The root canals were instrumented with Reciproc instruments up to the size 40/04 ISO. The teeth were divided into three groups (n = 30). The root canals of each group were rinsed accordingly: the control group 1: 5.25% sodium hypochlorite (NaOCl); the experimental group 2: smear layer removal (two times alternatively: 40% citric acid and 5.25% NaOCl) and NaOCl; the experimental group 3: smear layer removal (same as in group 2) and isopropyl alcohol. In each group the roots were further divided into 2 subgroups (n = 15). The root canals were obturated using warm vertical compaction technique of gutta-percha with AH Plus sealer marked with hydrophilic fluorescein (subgroup F) or hydrophobic porphyrin (subgroup P). After 72 h, one-millimeter-thick cross-sections were cut in two, five and eight millimeters distance from the apex. The depth of the penetration of the sealer into the dentinal tubules (resin tags) was measured with the use of a confocal laser microscope. Results: In of all the root parts, the longest resin tags were observed in group 2, whereas the shortest ones were found in group 1 (in the porphyrin subgroups all differences were statistically significant). Within the fluorescein subgroups, the differences between all groups were statistically significant in the middle section of the roots. In the apical and the coronal sections, significant differences were observed between group 1 and the other two groups. Conclusions: The isopropyl alcohol at the end of the irrigating protocol did not affect the higher sealer penetration of the sealer into the dentinal tubules compared with sodium hypochlorite. With the limitation of this study, the hydrophobic porphyrin may be considered as the favorable dye choice to stain endodontic sealers in further studies with confocal laser scanning microscopy, but the methods and reagents used should still be in the research phase.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call