Abstract

ObjectivesTo evaluate the bone changes around equicrestal and subcrestal implants, analyzing the effect of abutment height [short abutments (SA < 2 mm) and long abutments (LA > 2 mm)] and the three components of the peri‑implant soft-tissue phenotype. MethodsTwenty-six patients received 71 implants that were placed according to supracrestal tissue height (STH) in an equicrestal (n = 17), shallow subcrestal ≈1 mm (n = 33), or deep subcrestal ≈2 mm (n = 21) position. After 3 months of healing, rehabilitation was completed using metal-ceramic crowns on multi-unit abutments of 1.5 mm, 2.5 mm, or 3.5 mm in height, depending on the prosthetic space and STH. Longitudinal clinical parameters (STH, mucosal thickness, and keratinized mucosa width) and radiographic data [bone remodelling and marginal bone loss (MBL)] were collected at 3, 6, 12, and 24 months postsurgery. ResultsThe gain in STH was significantly greater around the implants placed in a subcrestal ≈2 mm position. After 2 years, the mean change in bone remodelling in the SA group was significantly greater than in the LA group. According to the multiple linear regression, bone remodelling depends primarily on abutment height (β = -0.43), followed by crestal position (β = 0.34), and keratinized mucosa width (β = -0.22), while MBL depends on abutment height (β = -0.37), and the patient's age (β = -0.36). ConclusionsImplants placed in an equicrestal or subcrestal ≈1 mm position with LA undergo less bone remodelling, while the lowest level of MBL occurs in subcrestal ≈2 mm implants with LA. Differing soft-tissue thicknesses combined with the use of either SA or LA produced significant intergroup differences in bone remodelling and MBL. Clinical significanceAbutment height is the most powerful predictor variable affecting bone remodelling and MBL. Depending on the dimensions of the peri‑implant soft-tissue phenotype, placing the implants subcrestally may also be a viable option to decrease bone remodelling and, consequently, reduce MBL. Clinical trial registrationidentification number: NCT05670340.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.