Abstract

In vascularized organ transplants, gender mismatches have higher rates of immunological rejection. We investigated the influence of gender incompatibility, including H-Y incompatibility, on corneal transplant graft rejection and failure. Patients were included who had undergone a first corneal transplant for keratoconus (KC), Fuchs endothelial dystrophy (FED), pseudophakic bullous keratopathy (PBK), infection and other indications. A Cox regression model was fitted for each indication to determine factors affecting graft failure and rejection at 5 years. The impact of gender, including H-Y, matching was analyzed after accounting for other factors, including known risk factors. Of 18 171 patients, 4314 had undergone a transplant for FED, 4783 for KC, 3669 for PBK, 1903 for infection and 3502 for other disorders. H-Y mismatched (male [M]→female [F]) corneas were at greater risk of graft failure or rejection. For FED, F→F were 40% less likely to fail (p < 0.0001) and 30% less likely to reject (p = 0.01); M→M were 20% less likely to fail (p = 0.04) and 30% less likely to reject (p = 0.01). For KC, M→M matched corneas were 30% less likely to fail (p = 0.05) and 20% less likely to reject (p = 0.01) compared with H-Y mismatches. H-Y antigen mismatched (M→F) patients were at greater risk of rejection or graft failure.