Nine endodontic instruments from different manufacturers (Reamers, K-files, Hedstrom files, K-Flex files, Flexofiles, S-files, Burns Unifiles, Flexicut files and Flex-R files) were used to prepare 180 simulated root canals in resin blocks. The instrument's ability to reproduce a theoretical pre-established ideal canal shape was assessed by comparing the original canal path with the resulting enlarged canal shape by a double exposure photographic method. The individual ability of each instrument to transport debris was also observed during instrumentation under a stereomicroscope. Regardless of the instrument type, none was able to reproduce ideal results; however, clinically acceptable results could be obtained with all of them. The coronal and apical debris transportation characteristics proved to be similar with all instruments.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.