The influences of the chromate quenching step and the surface chloride contamination levels of galvanized steel on the performance of duplex systems were studied. Steel panels were galvanized in a commercial steel bath adopting three different postdipping procedures. A comparative study of the galvanized steel, both painted and nonpainted, was performed by electrochemical techniques. It was verified that the chloride contamination level of the galvanized steel surfaces is the main cause of duplex system failures. An explanation for the influence of the chromate quenching on the performance of duplex systems was presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.