Abstract

This paper describes the results of an investigation into the surface heat flow distribution around GEL-99, a Geothermal Exploration Lease granted to Scopenergy Limited by the South Australian Government. I collated temperature and thermal conductivity data from a number of sources in order to construct one-dimensional thermal models of 30 petroleum industry wells. The data indicate a marked thermal conductivity contrast between the base of the Eromanga Basin sequence and the Cooper Basin sequence, resulting in a relatively high thermal gradient in the latter. Observed drill stem test temperatures support this prediction.Vertical heat flow within GEL-99 ranges from about 90 mW/m2 to over 110 mW/m2, averaging over 100 mW/m2. Heat flow drops off significantly towards and beyond the edge of the Big Lake Suite granodiorite. Observed values of heat flow cover a range of about 25 mW/m2. This variation can be attributed to a combination of a variable thickness of heat-generating material in the basement, and heat refraction through areas of relatively shallow basement.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.