Abstract
The influence of different artificial body fluids on metallic corrosion, all containing chloride ion, was investigated by measurements of open circuit potential, polarisation curves and electrochemical impedance on high speed steel, chosen owing to its high rate of corrosion. Two types of electrolyte fluid were studied, the first similar to saliva and the second to plasmatic serum and experiments were carried out over a period of immersion of 4h. Electrolytes similar to saliva were artificial saliva with and without lactic acid, and Glandosanethat contains sorbitol and Na- carboxymethylcellulose organic components. Similar to plasmatic serum were phosphate buffer saline (PBS) and Krebs-Ringer solution. It was found that the organic components in the fluids partially block the metal surface and reduce the corrosion rate. From the results obtained, an approximate order of corrosion rate was established as: Artificial saliva ~ Glandosane ~ Krebs- Ringer solution < Artificial saliva without lactic acid ~ PBS. It is demonstrated that the equivalence of these different body fluids as bathing solutions should not be assumed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.