Abstract

In this study, the sprayed concrete mix design was changed to make the concrete more pumpable and sprayable without increasing the amount of superplasticiser. This was achieved by use of an air entrainer to give good flowability and enhance pump-ability, and additionally some “slump killing” effect after placing. The effect of micro-air stability was checked by air content measurements on fresh concrete (NS-EN 12350-7) and comparison with compressive strength (NS-EN 12390-3), to find an optimal air-content for sprayed concrete. Also, the effect of air entrainment on the frost durability will be checked in later tests.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.