Abstract

Septic transfusion reactions are a principal cause of transfusion-related mortality. The frequency of detectable bacterial contamination is greater in platelets compared to other blood components because platelets are stored at room temperature. Most strategies outlined in the September 2019 FDA guidance require both aerobic culture (AC) and anaerobic culture (AnC) testing. We performed a systematic review and meta-analysis in an effort to provide the best available estimate of the effectiveness of AnC. Our analysis was performed according to published guidelines. Broad and context-specific meta-analyses of bacterial detection rates in platelets by AnC were performed to assess the practical effectiveness of AnC as a risk control measure. Seven studies with a total of 1767014 tested platelet components were included for analysis. With exclusion of positives due to Cutibacterium/Propionibacterium species and redundancy due to AC results, AnC detected 0·06 contamination events per thousand (EPT) components tested, twofold lower than the AC (0·12 EPT). Excluding Cutibacterium/Propionibacterium species, AnC detects occasional bacterial contamination events that are not detected by AC (~1 in 17000 platelet components).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.