Abstract

To determine a threshold of detection value for surface roughness of restorations by patients using their tongue. Samples of composite resin were finished with differing grades of abrasive. The surface roughness (Ra) was measured and representative scanning electro-micrographs taken. These were compared with labial enamel. Twenty-five volunteers were asked to rank them in order of perceived roughness using the tip of their tongue. These showed that the 60% of volunteers were able to rank the specimens correctly, and were able to distinguish differences in roughness values from between 0.25 and 0.50 microm. This range encompasses that of natural enamel. The subjects were able to distinguish lower roughness values than have previously been reported. It is concluded that when finishing restorations the surface should have a maximum roughness 0.50 microm if it is not to be detected by the patient.