Abstract

PurposeTo explore the value of clinical application with the whole process computed tomography (CT) guided percutaneous gastrostomy in esophageal tumor patients.Materials and methodsA consecutive series of 32 esophageal tumor patients in whom endoscopic gastrostomy or fluoroscopy guided gastrostomy were considered too dangerous or impossible due to the esophagus complete obstruction, complicate esophageal mediastinal fistula, esophageal trachea fistula or severe heart disease. All of the 32 patients were included in this study from 2 medical center and underwent the gastrostomy under whole process CT guided.ResultsAll of the gastrostomy procedure was finished successfully under whole process CT guided and the technical success rate was 100%. The average time for each operation was 27 min. No serious complications occurred and the minor complications occurred in 3 patients, including local infection, severe hyperplasia of granulation tissue and tube dislodgment. There were no procedure related deaths.ConclusionThe technical success rate of whole process CT guided percutaneous gastrostomy is high and the complication is low. This technique can be used feasible and effectively in some special patients.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call