to compare the degree of bacterial contamination of surgical instrument tables used in clean surgical procedures, either protected with plastic fields, sterilized with ethylene oxide, or disinfected with 70% alcohol and 1% iodine solutions. This is a randomized clinical trial in which samples were collected from the surfaces of surgical instrument tables before and after each procedure. Microbiological analysis was performed to identify microorganisms and their respective antimicrobial resistance. Bacterial growth in the surgeries using sterilized plastic was 5.71% before and 28.6% after surgery and, 2.9% and 45.7% respectively in surgeries using disinfection with 70% alcohol and 1% iodine solutions; no statistical difference was found between the methods. both methods present similar protection, however, 70% alcohol and 1% iodine do not generate solid waste.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.