Abstract

A poor depiction of occupant behavior in building performance simulation frequently results in substantial divergences between real and simulated results. The problem may be of particular concern with simulation supporting the renovation of older multi-unit residential buildings, buildings whose occupants use windows for temperature control even during heating season. Here, we investigated the impact of window operation models (as well as other occupant behaviors) on simulated energy performance in university residence halls. Based on environmental monitoring, along with information collected from occupant surveys and wearable devices, we estimated air exchange rates and developed a probabilistic window-operation prediction model. The data were collected in 76 dormitory rooms sampled from a pre-renovated historic building and two similar buildings. We then evaluated the window-operation model’s predictive performance in 15 dormitory rooms in the post-renovated building with new occupants. The results of our predictive model were also compared with previously reported window-operation models. We implemented each window-operation model in a calibrated EnergyPlus building performance model, comparing the results of each simulation to metered hourly steam consumption. The impact of the different window operation models on simulated heating energy use was significant (annual error ranging from 0.2% to 10%). Our model demonstrated the highest capability of predicting window state (accuracy=85.8%) and steam use (NMBE=−0.2%); however, some previously published windowoperation models also produced satisfactory performance, implying that such models may be generalizable to some extent. The results suggest that data collected from somewhat ubiquitous indoor environmental quality sensors can glean insights into occupant behavior for building performance simulation. Furthermore, the energy impacts resulting from the variations in occupant behavior studied here were large enough to show that the choice of behavior model can have meaningful implications for real-world applications, such as estimating saving from heating and lighting system upgrades.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.