Abstract

The purpose of this study was to examine the effect of venous occlusion per se on forearm muscle blood flow, as determined by the near-infrared spectroscopy (NIRS) venous occlusion technique (NIRS-VOT). NIRS data were obtained from the flexor digitorum superficialis (FDS) muscle on the dominant arm of 16 young, ostensibly healthy participants (14 men and two women; 30±6year; 73±7kg). Participants completed a series of five venous occlusion trials while seated at rest, and a series of 12 venous occlusion trials during a reactive hyperaemia induced by 5min of forearm arterial occlusion. The NIRS-VOT was used to assess FDS muscle blood flow (Q˙mus), beat-by-beat, over the first four cardiac beats during venous occlusions. Q˙mus was also reported as a cumulative value, wherein the first two, first three and first four cardiac beats were used to calculate muscle blood flow. We observed that Q˙mus was highest when calculated over the first cardiac beat during venous occlusions performed at rest and throughout reactive hyperaemia (P<0·05). Moreover, the inclusion of more than one cardiac beat in the calculation of Q˙mus underestimated muscle blood flows, irrespective of the prevailing level of arterial inflow. These findings support the idea that venous occlusion per se affects the measurement of Q˙mus via the NIRS-VOT. Accordingly, it is recommended that Q˙mus is determined over the first cardiac beat when using the NIRS-VOT to assess microvascular blood flow of human forearm muscles.