Abstract

Automatic calibration of complex hydro-ecological models is an increasingly important issue which involves making decisions. One of the most relevant is the choice of the objective function, but its effects have been scarcely studied in complex models. We have used the SWAT model to assess the impact of the objective function for a multi-site (4 stations) and multi-variable (OrgP, OrgN, NO3−, PO43−) calibration of the Odense catchment (Denmark). Six calibration schemes were tested, varying the objective function and the nutrient fractions targeted. The best performance metrics (R2, NSE, PBIAS) were obtained when using NSE as objective function and targeting N-fractions and P-fractions separately. The scheme was validated in another SWAT set-up in northern Denmark. Although NSE is often questioned, we found it as an adequate objective function when addressing a multi-site and multi-variable calibration. Our findings may serve as guideline for hydro-ecological modellers, being useful to achieve watershed management goals.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.