Abstract
ABSTRACTWe investigate the impact of local climatic variations on the energy performance of buildings by conducting simulations using weather files generated from high-resolution measurements covering 33 stations within a 77 km2 area in southern Vancouver Island, British Columbia, Canada. Weather files were created by resampling the data and applying appropriate models to obtain unmeasured values. The difference in microclimate has been analysed statistically and graphically; average annual temperature varies by around 1°C, and at certain times there is a 6°C variation across the (very small) region.Building energy simulations of a small naturally ventilated office building and a larger air-conditioned building were performed using EnergyPlus for all weather files. Significant variation is found spatially and temporally which would have substantial implications for building design and energy use. The variation in annual heating energy use is ±5% of the mean, equivalent to 18 kWh/m2/a, with even greater relative variation in cooling energy use.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.