Abstract
Exposure of reinforced concrete structural elements to high temperatures, e.g. fire, remains one of the serious potential risks to such structures. This exposure can lead to losses in concrete structural capacity, possible plastic deformation of embedded steel and loss of bond between reinforcing steel and concrete. The level of temperature and the method of extinguishing the fire alter the microstructure of reinforcing steel bars. This microstructure alteration changes the corrosion behavior of steel in such structures, when exposes to chloride ions. The present study was undertaken to determine the impact of exposure of steel to high temperature and the method of extinguishing the fire on its corrosion behavior in alkaline environment of concrete in presence of chloride ions. Results indicated that exposure of steel to high temperatures, regardless of its level; made steel more susceptible to corrosion compared to the reference case, when steel was kept at room temperature. The worst case happened for the steel exposed to 850°C for an hour, then cooled rapidly in water, where the corrosion rate increased approximately 60% in chloride contaminated concrete pore solution.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.