Abstract
The purpose of this study is to compare the initial outcomes of using the Chocolate balloon pre-dilatation (CLP) and sequential enlarging angioplasty pre-dilatation (sequential balloon pre-dilation [SP]) techniques versus the conventional balloon pre-dilatation (CP) method prior to drug-coated balloon (DCB) treatment for femoropopliteal (FP) lesions. This was a retrospective analysis of prospectively collected data from the CIVILIAN (Clinical InVestigation of different lesIon preparation modaLIty followed by DCB in femoropopliteal Artery occlusioN disease) registry. Between March 2021 and November 2022, 3 pre-dilation techniques used prior to the DCB angioplasty were included. The study endpoint included intraoperative finial severe dissection after provisional stent placement, bailout stenting rate, the diameter of the largest pre-dilation balloon and DCB, as well as major adverse events (MAEs), including death, major limb amputation, or target vessel revascularization at 6 months. During the study period, 435 limbs (429 patients) were pre-dilated before DCB treatment in FP lesions, 166 limbs were pre-dilated with Chocolate balloons, 93 limbs with sequential enlarging balloon pre-dilation technique, and 176 limbs with CP. The largest pre-dilation balloon was significantly larger in CLP and SP groups than that in the CP group (CLP 4.74±0.52 mm vs CP 4.36±0.64 mm, p<0.001; SP 4.82±0.69 mm vs CP 4.36±0.63 mm, p<0.001). A consistent result was shown in DCB diameter (CLP 4.86±0.44 mm vs CP 4.71±0.51 mm, p=0.003; SP 4.90±0.58 mm vs CP 4.71±0.51 mm, p=0.006). The bailout stenting rate was significantly lower in the CLP group than that in the CP group (18.1% vs 30.1%, p=0.011). The rates of MAEs at 6 months in the CLP and SP groups were comparable to those in the CP group (7.2% and 8.6% vs 6.3%, p>0.05). The risk for intraoperative bailout stenting rate was related to TASC D classification (3.59, 95% CI: 1.83-7.05, p<0.001), chronic total occlusion (CTO) lesion (1.82, 95% CI: 1.07-3.10, p=0.028), as well as pre-dilated with the conventional balloon (1.64, 95% CI: 1.00-2.69, p=0.048). By utilizing chocolate balloon and sequential enlarging angioplasty, it becomes possible to use larger pre-dilation balloons and DCBs. In addition, the use of the chocolate balloon can significantly reduce the need for bailout stenting when compared with conventional balloons. The utilization of a chocolate balloon and sequential enlarging angioplasty has emerged as a promising technique for angioplasty procedures. This approach allows for the use of larger pre-dilation balloons and drug-coated balloons. The use of the chocolate balloon can significantly reduce the need for bail-out stenting when compared to conventional balloons. Further research is required to determine the impact of vessel preparation techniques on the primary patency.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.