Abstract

The TRS‑483, an IAEA/AAPM International Code of Practice on dosimetry of small static photon fields, underwent testing via an IAEA coordinated research project (CRP). Alongside small field output factors (OFs) measurements using active dosimeters by CRP participants, the IAEA Dosimetry Laboratory received a mandate to formulate a remote small field dosimetry audit method using its passive dosimetry systems. This work aimed to develop a small field dosimetry audit methodology employing radiophotoluminescent dosimeters (RPLDs) and radiochromic films. The methodology was subsequently evaluated through a multicenter pilot study with CRP participants. The developments included designing and manufacturing a dosimeter holder set and the characterization of an RPLD system for measurements in small photon fields using the new holder. The audit included verification of small field OFs and lateral beam profiles for small fields. At first, treatment planning system (TPS) calculated OFs were checked against a reference data set that was available for conventional linacs. Second, calculated OFs were verified through the RPLD measurement of point doses in a machine-specific reference field, 4cm × 4cm, 2cm × 2cm, and 1cm × 1cm, corresponding size circularfields or nearest achievable field sizes. Lastly, profile checks in in-plane and cross-plane directions were done for the two smallest fields by comparing film measurements with TPS calculations at 20%, 50%, and 80% isodose levels. RPLD correction factors for small field measurements were approximately unity. However, they influenced the dose determination's overall uncertainty in small fields, estimated at 2.30% (k=1 level). Considering the previous experience in auditing reference beam output following the TRS-398 Code of Practice, the acceptance limit of 5% for the ratio of the dose determined by RPLD to the dose calculated by TPS, DRPLD/DTPS, was considered adequate. The multicenter pilot study included 15 participants from 14 countries (39 beams). Consistent with the previous findings, the results of the OF check against the reference data confirmed that TPSs tend to overestimate OFs for the smallest fields included in this exercise. All except three RPLD measurement results were within the acceptance limit, and the spread of results increased for smaller field sizes. The differences between the film measured and TPS calculated dose profiles were within 3mm for most of the beams checked; deviated results revealed problems with TPS commissioning and calibration of the treatment unit collimation systems. The newly developed small field dosimetry audit methodology proved effective and successfully complemented the CRP OF measurements by participants with RPLD audit results.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call