Abstract
The surface heating fuser, required in the EP printer from the energy saving standpoint, sometimes causes the horizontal banding image. This type of banding is not seen with conventional fuser such as the heat roller type. We found that the root cause of this phenomenon is the AC current leakage from fuser to transfer area. This paper reports that the RC circuit model between fuser and transfer area can simulate this phenomenon well. According to this model, solutions are as follows;1. To increase the reactance of fuser heater and film, preventing the AC current leakage to the media.2. To add the by-pass circuit from fuser film inside to the ground, preventing the AC current leakage to the media.3. To add the by-pass circuit from pressure roller to the ground, preventing the AC current leakage to the media.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.