The High Acceptance Di-Electron Spectrometer (HADES) at the heavy ion synchrotron SIS of GSI, Darmstadt, is a high-resolution second generation detector system for lepton pair spectroscopy. Its low-mass tracking system consists of two pairs of planes of trapezoidally shaped Multiwire Drift Chambers (MDC), installed on either side of a superconducting toroidal magnet. This paper summarizes some experiences with the construction and the in-beam operation of the six large-area chambers produced by Forschungszentrum Rossendorf. Studies on creeping of aluminum wires over a period of three years are presented. In addition, the observation of growth of filaments with various shapes and sizes in one of the chambers used in-beam will be discussed in detail.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.