Abstract

Three gas-liquid chromatographic (G.L.C.) procedures discussed have been designed around the four "esses" of detection tests--speed, sensitivity, simplicity, and specificity. These techniques are admirably applicable to the very low plasma drug levels encountered in blood testing under pre-race conditions. The methods are equally applicable to post-race testing procedures, where both blood and urine samples are tested. Drugs can only rarely be detected by the electron capture detector (E.C.D.) without a prior derivatization step, which conveys to the drug(s) high electron affinity. Because of broad applicability, two derivatizing agents, heptafluorobutyric (HFBA) and pentafluorpropionic (PFPA) anhydrides are employed. The three techniques, allowing broad coverage of various drug classes are: 1) direct derivatization of drugs to form strongly electron capturing amides and esters. 2) reductive fragmentation of drugs with lithium aluminum hydride to form alcohols, with conversion to ester derivatives. 3) oxidative fragmentation of drugs with potassium dichromate to form derivatizable groups, followed by direct derivatization.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.