Abstract
This paper gives a brief overview of process control in slab reheating furnaces, zooming on the so-called “funnel-concept”, as this is implemented at Corus IJmuiden this year. The control automation in reheating furnaces at Corus started in 1970. In 1985-1990 an on-line slab temperature calculation and control system has been developed and implemented at pusher-and walking-beam furnaces. Ongoing development of this model resulted in a control strategy where the target-heating curve of each individual slab was extended by an upper and lower limit, of which the interval at the entrance gradually diminished to the end of a zone: the funnel model.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.