The performance of a purely digital evaluation system for photographic PIV recordings is described. High resolution digital images are obtained from the 35 mm negatives using a commonly available slide scanner. Together with the continually improving capabilities of standard computers, this evaluation system is a cost effective alternative to the traditional analog optical/digital (Young's fringe method) and purely optical PIV interrogation systems. Compared to the optical systems the fully digital evaluation can provide a higher spatial resolution while maintaining a similar measurement uncertainty. Using actual PIV recordings absolute measurement uncertainties are obtained and further predictions toward optimal displacement data recovery are made with the aid of Monte-Carlo simulations. Measurement uncertainties are minimized for particle image diameters on the order of 2 pixels while the reduction of the image depth (i.e. bits/pixel) has little effect. The overall performance of the described digital evaluation is compared to two types of optical evaluation systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.