Abstract

BackgroundFractured connections between implants and implant abutments or abutment screws are frequently encountered in a clinical setting. The purpose of this study was to investigate fracture strength using a torsion test at the interface between the implant and the abutment. MethodsThirty screw-type implant with diameters of 3.3, 3.8, 4.3, 5.0, and 6.0 mm were submitted to a torsion test. Implants of each size were connected to abutments with abutment screws tightened to 20 N · cm. Mechanical stress was applied with a rotational speed of 3.6 °/min until fracture occurred, and maximum torque (fracture torque) and torsional yield strength were measured. The mean values were calculated and then compared using Tukey’s test. The abutments were then removed, and the implant-abutment interfaces were examined using a scanning electron microscope (SEM).ResultNo significant differences in mean fracture torque were found among 3.3, 3.8, and 4.3 mm-diameter implants, but significant differences were found between these sizes and 5.0 and 6.0 mm-diameter implants (p < 0.01). Concerning mean torsional yield strength, significant differences were found between 3.3, 3.8, and 4.3 mm-diameter and 5.0 and 6.0 mm-diameter implants (p < 0.01). Observations under the SEM showed that all the projections of the abutment corresponding to the internal notches of the implant body had been destroyed.ConclusionsSmaller diameter implants demonstrated lower fracture torque and torsional yield strength than implants with larger diameters. In internal tube-in-tube connections, three abutment projections corresponding to rotation-prevention notches were destroyed in each implant.

Highlights

  • Fractured connections between implants and implant abutments or abutment screws are frequently encountered in a clinical setting

  • The maximum torque and torsional yield strength were measured in each specimen

  • No significant differences in mean maximum fracture torque were found among 3.3, 3.8, and 4.3 mm-diameter implants, but significant differences were found between these sizes and 5.0 and 6.0 mm-diameter implants (p < 0.01)

Read more

Summary

Introduction

Fractured connections between implants and implant abutments or abutment screws are frequently encountered in a clinical setting. The purpose of this study was to investigate fracture strength using a torsion test at the interface between the implant and the abutment. The degree of mechanical integrity at the implant-abutment interface depends on screw preload, abutment connection design, the fitness of all components, and dynamic loading conditions. Fractures of the internal or external connection between implants and implant abutments or abutment screws are encountered in the clinical setting [1,2,3]. Fractures may occur as a result of excessive axial forces (bending moments), horizontal loading, or rotational. The maximum torsional strength and proportional limited strength on crown and tooth restoration materials were measured, and the values were compared with a mechanical bending and pull test value [14]

Objectives
Methods
Results
Discussion
Conclusion