Abstract
The objective of this study is to establish the detection rate of sentinel lymph node (SLN) biopsies and to determine the sensitivity and false-negative rate of SLN biopsies compared with those of systematic pelvic and para-aortic lymphadenectomies in endometrial cancer. This prospective cohort study enrolled patients with endometrial cancer who were scheduled for surgical staging. Patients with a history of chemotherapy or radiotherapy, an abnormal liver function test, or an allergy to indocyanine green (ICG) were excluded. All patients underwent surgical staging with an ICG injection at the cervix. SLNs were identified by a near-infrared fluorescent camera. All SLNs were sent to a pathologist for ultrastaging. From November 2019 to June 2023, 142 patients underwent SLN mapping and surgical staging. SLNs were not detected bilaterally in 8 patients. The detection rate of the SLN biopsies in this study was 91.2%. Thus, the accuracy of the SLN biopsies was 97.6%. The sensitivity for finding metastatic SLNs was 84.2%, with a negative predictive value of 97.22%. A SLN biopsy in endometrial cancer has a high detection rate and high accuracy. However, surgical expertise and a learning curve are required.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.