Abstract

Abstract The flow rate of a formulation through hand‐held u.l.v. equipment is determined by the viscosity of the product and the diameter of the restrictor orifice fitted. A convenient flow rate onto the atomiser head is 1 ml s−1. Most hand‐held u.l.v. equipment is supplied with several interchangeable restrictors allowing the spray operator to choose one suitable for the formulation to be applied. The flow rates of four blank (containing no pesticide) u.l.v. formulations, each of different viscosity, through five different pieces of application equipment were investigated. The results are tabulated so that the spray operator can choose an appropriate restrictor to fit to the hand‐held u.l.v. equipment he wishes to use. To use this information the operator must know the viscosity of the product at the temperature he intends to spray at It should be emphasised that the results presented in no way eliminate the need for a calibration run before commencing spraying.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.