Abstract
Background: Within 30 seconds of birth ILCOR recommends that newborns should be warmed, have their airways opened and breathing and heart rate (HR) assessed. By 60 seconds, respiratory support given if appropriate and oximetry considered. Objectives: To determine time taken to perform DR interventions recommended by ILCOR; and the proportion with the recommended interventions performed within the allotted time. Methods: Using video recordings we measured the time taken to warm, assess HR, attach an oximeter and give respiratory support; and determined which infants had the recommended interventions completed by 30 and 60 seconds. Results: We reviewed recordings of 23 infants [mean(SD) gestational age & birth weight 29(3) weeks & 1312(594)g]. All interventions took longer than recommended (Table1). Four infants were not on the trolley within 30 seconds. By 60 seconds, 10/21 infants were in polyethylene-bags, 3/23 had their HR determined and 12/23 had an oximeter on. No infant had all tasks completed within 30 or 60 seconds of birth Conclusion: Our newborns were not managed within the time-frame recommended by ILCOR. The 30-second intervals recommended may be too short.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.