The first DC performance experiments of ITER correction coil (CC) conductor short sample have been carried out in the conductor test facility of Institute of Plasma Physics, CAS (ASIPP) in January this year. Those experiments aim to investigate the DC performance of ITER CC conductor. The tested conductor short sample is bended as a half circle with the diameter of 270mm to meet the background magnetic field shape. The half circle part of sample is longer than the final twist pitch. The current sharing temperature (Tcs) in the 3.86T external magnetic field (Bex), ≤12kA could be measured including the critical current (Ic) run. There is no obvious impact of 1000 cycles on DC performance. Those measured Tcs results are in agreement with the expected results from strand scaling.