Abstract
In consideration of the low efficiency of the organic Rankine cycle (ORC) with low-grade heat source (LGHS), an organic Rankine cycle with ejector (EORC) and a double organic Rankine cycle (DORC) based on the ORC is introduced in this paper. The thermodynamic first law and second law analysis and comparison on the ORC, EORC and DORC cycles are conducted on the cycle’s power output, thermal efficiency, exergy loss and exergy efficiency. Water is chosen as the LGHS fluid, and the same temperature and mass flow rate of the water is the standard condition for the comparative analysis on the cycles. The emphasis is on the thermodynamic performance at the maximum net power output of the cycles. The results show the power output is higher in the EORC and DORC compared to the ORC. And the cycle’s exergy efficiency could be ranked from high to low: DORC>EORC>ORC.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.