Abstract
This paper describes the proton injection kicker system designed to accept protons from the Fermilab Conventional Main Ring in the Tevatron Superconducting Ring. The pulse forming network (PFN) based thyratron switch tube pulser delivers a 100 ns rise, 200 ns fall, 40 KV pulse to a 6.25 ohm traveling wave magnet load. The pulse duration is adjustable up to a maximum of ~ 22 μsec. The design philosophy, magnet parameters, and system performance are discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.