Abstract

BackgroundReconstruction of the aorto-iliac segment with femoral vein (FV) as substitute for infected synthetic grafts or mycotic aneurysms constitutes the most sustainably convenient alternative. The aim of this study was to evaluate the long-term outcome of up to 16 years of follow-up, analysing the morphologic adaption of the FV with special emphasis on the distal and proximal anastomoses.MethodsWe conducted a retrospective study of 22 patients with 109 computed tomography angiograms (CTAs) treated between August 2001 and January 2020 in case of aortic infection/aortitis. Morphologic changes like anastomotic dilatation/stenosis as well as changes of FV wall thickness were retrospectively analysed in pre- and postoperative CTAs.ResultsElective procedure was done in 17/22 (77%) cases, and 5/22 (23%) patients required emergent surgery. The median follow-up was 91.5 months (P25;P75 = 21;117). Cross-sectional diameter of proximal (20.38 ± 3.77 vs 22.04 ± 3.97 mm, p = 0.007) and distal anastomoses (13.05 ± 4.23 vs 14.61 ± 5.19 mm, p = 0.05) increased significantly, as well as the proximal and distal anastomotic areas (3.36 ± 1.29 vs 4.32 ± 1.63 mm2, p = 0.04 and 0.99 ± 0.48 vs 1.25 ± 0.72 mm2, p = 0.023, respectively). Venous wall thickness was significantly reduced at the anastomotic site (1.74 ± 0.46 vs 1.24 ± 0.31 mm, p = 0.001). The upper thigh diameter did not differ before and after harvesting of the FV (161.6 ± 29.1 vs. 178.2 ± 23.3 mm, p = 0.326, respectively).ConclusionThis long-term CTA follow-up study showed that the FV wall becomes thinner at the anastomotic site, and the anastomoses dilate with time without rupture. The FV is a durable conductor after replacement of the aorto-iliac segment due to aortic infection. Further CTA studies from more centres are warranted to evaluate the risk of vein rupture.

Highlights

  • Reconstruction of the aorto-iliac segment with autologous femoral vein (FV) is one of several techniques for the treatment of mycotic aortic aneurysm as well as for replacement of infected prosthetic grafts

  • We conducted a retrospective study of 22 patients with 109 computed tomography angiograms (CTAs) treated between August 2001 and January 2020 in case of aortic infection/aortitis

  • The upper thigh diameter did not differ before and after harvesting of the FV (161.6 ± 29.1 vs. 178.2 ± 23.3 mm, p = 0.326, respectively). This long-term CTA follow-up study showed that the FV wall becomes thinner at the anastomotic site, and the anastomoses dilate with time without rupture

Read more

Summary

Introduction

Reconstruction of the aorto-iliac segment with autologous femoral vein (FV) is one of several techniques for the treatment of mycotic aortic aneurysm (mAAA) as well as for replacement of infected prosthetic grafts. This technique yields a good infection control and acceptable longterm survival [1,2,3,4]. Few studies have reported long-term outcome results after usage of FV as graft material for reconstruction of the aorto-iliac segment [13]. The aim of this study was to evaluate the long-term outcome of up to 16 years of follow-up, analysing the morphologic adaption of the FV with special emphasis on the distal and proximal anastomoses

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call